FULL DETAILS (Read-only)  -> Click Here to Create PDF for Current Dataset of Trial
CTRI Number  CTRI/2024/01/062073 [Registered on: 30/01/2024] Trial Registered Prospectively
Last Modified On: 22/01/2024
Post Graduate Thesis  Yes 
Type of Trial  Interventional 
Type of Study   Dentistry 
Study Design  Other 
Public Title of Study   Accuracy of various digital scanners on milled crowns. A Clinical trial. 
Scientific Title of Study   Comparison of the accuracy of various digital scanners on ceramic milled crowns using the silicone replica method. A Clinical Trial. 
Trial Acronym  nil 
Secondary IDs if Any  
Secondary ID  Identifier 
NIL  NIL 
 
Details of Principal Investigator or overall Trial Coordinator (multi-center study)  
Name  Sashwat Sathish 
Designation  Post Graduate 
Affiliation  Saveetha Denatal College and Hospital, Saveetha Institute of medical and technical sciences 
Address  Department of Endodontics and Conservative dentistry, Saveetha Dental College and Hospital 162, Poonamallee High Rd, Velappanchavadi, Chennai

Chennai
TAMIL NADU
600077
India 
Phone  8754555886  
Fax    
Email  152106007.sdc@saveetha.com  
 
Details of Contact Person
Scientific Query
 
Name  Manish Ranjan 
Designation  Professor 
Affiliation  Saveetha Denatal College and Hospital, Saveetha Institute of medical and technical sciences 
Address  Department of Endodontics and Conservative dentistry, Saveetha Dental College and Hospitals 162, Poonamallee High Rd, Velappanchavadi, Chennai

Chennai
TAMIL NADU
600077
India 
Phone  9543445029  
Fax    
Email  manis@saveetha.com  
 
Details of Contact Person
Public Query
 
Name  Manish Ranjan 
Designation  Professor 
Affiliation  Saveetha Denatal College and Hospital, Saveetha Institute of medical and technical sciences 
Address  Department of Endodontics and Conservative dentistry, Saveetha Dental College and Hospitals 162, Poonamallee High Rd, Velappanchavadi, Chennai


TAMIL NADU
600077
India 
Phone  9543445029  
Fax    
Email  manis@saveetha.com  
 
Source of Monetary or Material Support  
Sashwat Sathish Post Graduate, Department of Endodontics and Conservative dentistry, Saveetha Dental College and Hospitals, 
 
Primary Sponsor  
Name  Sashwat Sathish 
Address  162, Poonamallee High Rd, Velappanchavadi, Chennai, Tamil Nadu 600077 
Type of Sponsor  Other [Self] 
 
Details of Secondary Sponsor  
Name  Address 
NIL  NIL 
 
Countries of Recruitment     India  
Sites of Study  
No of Sites = 1  
Name of Principal Investigator  Name of Site  Site Address  Phone/Fax/Email 
sashwat sathish  Saveetha Dental college and hospital  Department of Endodontics and Conservative dentistry,162, Poonamallee High Rd, Velappanchavadi, Chennai, Tamil Nadu 600077
Chennai
TAMIL NADU 
8754555886

152106007.sdc@saveetha.com 
 
Details of Ethics Committee  
No of Ethics Committees= 1  
Name of Committee  Approval Status 
Institutional Human Ethical Comittee  Approved 
 
Regulatory Clearance Status from DCGI  
Status 
Not Applicable 
 
Health Condition / Problems Studied  
Health Type  Condition 
Patients  (1) ICD-10 Condition: K049||Other and unspecified diseases ofpulp and periapical tissues,  
 
Intervention / Comparator Agent  
Type  Name  Details 
Comparator Agent  control- 3shape trios intraoral scanner Intervention - Prime scan intraoral scanner   scans will be taken to place a crown in molars post root canal therapy by both intraoral scanners and the marginal fit is checked intra orally 
Intervention  control- 3shape trios intraoral scanner Intervention - Prime scan intraoral scanner  scans will be taken to place a crown in molars post root canal therapy by both intraoral scanners and the marginal fit is checked intra orally 
 
Inclusion Criteria  
Age From  18.00 Year(s)
Age To  80.00 Year(s)
Gender  Both 
Details  Presence of adjacent and opposing teeth
Age – 18 years and above
RCT treated teeth
Tessera milling as standard
 
 
ExclusionCriteria 
Details  Absence of adjacent and opposing teeth.
Unrestorable teeth.
Patient with limited mouth opening and TMJ issued.
Lower incisors
 
 
Method of Generating Random Sequence   Not Applicable 
Method of Concealment   Not Applicable 
Blinding/Masking   Not Applicable 
Primary Outcome  
Outcome  TimePoints 
To compare the accuracy of CEREC Primescan and 3Shape TRIOS using the silicone replica technique to measure the bi-planar fit at 20 points for milled ceramic crowns.
 
Nil
No follow up 
 
Secondary Outcome  
Outcome  TimePoints 
Time taken for scanning to be done & time taken to design the crown will be recorded  Nil
No follow up 
 
Target Sample Size   Total Sample Size="17"
Sample Size from India="17" 
Final Enrollment numbers achieved (Total)= "Applicable only for Completed/Terminated trials"
Final Enrollment numbers achieved (India)="Applicable only for Completed/Terminated trials" 
Phase of Trial   Phase 1 
Date of First Enrollment (India)   01/02/2024 
Date of Study Completion (India) Applicable only for Completed/Terminated trials 
Date of First Enrollment (Global)  Date Missing 
Date of Study Completion (Global) Applicable only for Completed/Terminated trials 
Estimated Duration of Trial   Years="0"
Months="4"
Days="0" 
Recruitment Status of Trial (Global)   Not Applicable 
Recruitment Status of Trial (India)  Not Yet Recruiting 
Publication Details   N/A 
Individual Participant Data (IPD) Sharing Statement

Will individual participant data (IPD) be shared publicly (including data dictionaries)?  

Response - YES
  1. What data in particular will be shared?
    Response - Individual participant data that underlie the results reported in this article, after de-identification (text, tables, figures, and appendices).

  2. What additional supporting information will be shared?
    Response -  Study Protocol
    Response -  Statistical Analysis Plan
    Response - Informed Consent Form
    Response - Clinical Study Report

  3. Who will be able to view these files?
    Response - Anyone

  4. For what types of analyses will this data be available?
    Response - To achieve aims in the approved proposal.

  5. By what mechanism will data be made available?
    Response - Proposals should be directed to [152106007.sdc@saveetha.com].

  6. For how long will this data be available start date provided 31-03-2024 and end date provided 01-01-2025?
    Response - Immediately following publication. No end date.

  7. Any URL or additional information regarding plan/policy for sharing IPD? 
    Additional Information - NIL
Brief Summary  

Aim:

To compare the clinical accuracy of Primescan Intra Oral Scanner and 3Shape TRIOS post milling via silicone replica method

 

Null Hypothesis:

There is no difference in accuracy between the intra-oral scanners 3Shape TRIOS and Primescan.

 

Alternate Hypothesis:

There is a difference in accuracy between the intra-oral scanners 3Shape TRIOS and Primescan.


 
Close