FULL DETAILS (Read-only)  -> Click Here to Create PDF for Current Dataset of Trial
CTRI Number  CTRI/2021/07/034529 [Registered on: 02/07/2021] Trial Registered Prospectively
Last Modified On: 02/07/2021
Post Graduate Thesis  No 
Type of Trial  Interventional 
Type of Study   Surgical/Anesthesia 
Study Design  Randomized, Parallel Group Trial 
Public Title of Study   Comparison between direct feel method for radial artery cannulation and waveform visualization method in adult cardiac surgical patients 
Scientific Title of Study   Comparison between digital palpation technique for radial artery cannulation and transducer technique in adult cardiac surgical patients 
Trial Acronym   
Secondary IDs if Any  
Secondary ID  Identifier 
NIL  NIL 
 
Details of Principal Investigator or overall Trial Coordinator (multi-center study)  
Name  PRASAD S R 
Designation  Associate Professor 
Affiliation  Sri Jayadeva institute of cardiovascular sciences 
Address  Sri Jayadeva institute of cardiovascular sciences,department of anesthesia, Bannerghatta Main Road, Phase 3, Jayanagara 9th Block, Jayanagar, Bengaluru,
Bannerghatta Main Road, Phase 3, Jayanagara 9th Block, Jayanagar, Bengaluru, Karnataka 560069
Bangalore
KARNATAKA
560069
India 
Phone  9886086232  
Fax    
Email  drprasadsr@gmail.com  
 
Details of Contact Person
Scientific Query
 
Name  PRASAD S R 
Designation  Associate Professor 
Affiliation  Sri Jayadeva institute of cardiovascular sciences 
Address  Sri Jayadeva institute of cardiovascular sciences,department of anesthesia, Bannerghatta Main Road, Phase 3, Jayanagara 9th Block, Jayanagar, Bengaluru,
Bannerghatta Main Road, Phase 3, Jayanagara 9th Block, Jayanagar, Bengaluru, Karnataka 560069
Bangalore
KARNATAKA
560069
India 
Phone  9886086232  
Fax    
Email  drprasadsr@gmail.com  
 
Details of Contact Person
Public Query
 
Name  PRASAD S R 
Designation  Associate Professor 
Affiliation  Sri Jayadeva institute of cardiovascular sciences 
Address  Sri Jayadeva institute of cardiovascular sciences,department of anesthesia, Bannerghatta Main Road, Phase 3, Jayanagara 9th Block, Jayanagar, Bengaluru,
Bannerghatta Main Road, Phase 3, Jayanagara 9th Block, Jayanagar, Bengaluru, Karnataka 560069
Bangalore
KARNATAKA
560069
India 
Phone  9886086232  
Fax    
Email  drprasadsr@gmail.com  
 
Source of Monetary or Material Support  
Sri Jayadeva institute of cardiovascular sciences 
 
Primary Sponsor  
Name  Sri Jayadeva Institute of Cardiovascular Sciences and Researc 
Address  Bannerghatta Main Rd, Phase 3, Jayanagara 9th Block, Jayanagar, Bengaluru, Karnataka 560069 
Type of Sponsor  Research institution and hospital 
 
Details of Secondary Sponsor  
Name  Address 
NIL  NIL 
 
Countries of Recruitment     India  
Sites of Study  
No of Sites = 1  
Name of Principal Investigator  Name of Site  Site Address  Phone/Fax/Email 
Prasad S R  Sri Jayadeva Institute of Cardiovascular Sciences and Research  Department of anesthesia,1st and 2nd floor operation theater, Sri Jayadeva Institute of Cardiovascular Sciences and Research Jayanagar 9th Block, Bannerghatta Road Bangalore - 560 069 Karnataka, India
Bangalore
KARNATAKA 
9886086232

drprasadsr@gmail.com 
 
Details of Ethics Committee  
No of Ethics Committees= 1  
Name of Committee  Approval Status 
SRI JAYADEVA INSTITUTE ETHICS COMMITTEE  Approved 
 
Regulatory Clearance Status from DCGI  
Status 
Not Applicable 
 
Health Condition / Problems Studied  
Health Type  Condition 
Patients  (1) ICD-10 Condition: I251||Atherosclerotic heart disease of native coronary artery, (2) ICD-10 Condition: I083||Combined rheumatic disorders of mitral, aortic and tricuspid valves, (3) ICD-10 Condition: O||Medical and Surgical, (4) ICD-10 Condition: I52||Other heart disorders in diseasesclassified elsewhere,  
 
Intervention / Comparator Agent  
Type  Name  Details 
Comparator Agent  blind palpatory technique  After palpating the artery cannula is inserted once backflow in the flash chamber is seen ,cannula is threaded into the artey blindly assuming that the cannula to be inside the artery 
Intervention  Transducer technique for radial artery cannulation  A 20g cannula connected to a transducer with continuous monitoring for the arterial pressure waveform is used to guide the cannula into the artery, which provides definitive evidence of cannula inside the artery, once cannulation is done the procedure is completed but the patient will be observed for 24 hours for any complications 
 
Inclusion Criteria  
Age From  18.00 Year(s)
Age To  60.00 Year(s)
Gender  Both 
Details  hundred patients posted for cardiac surgery of either sex aged between 18 to 60 years 
 
ExclusionCriteria 
Details  • Patients with previous attempts at arterial cannulation during the same
• unstable patient in whom an arterial line had to be placed before the study, randomization will be excluded.
• Patients with peripheral vascular disease
• Patients with subclavian artery stenosis
• Abnormal Allen’s test
 
 
Method of Generating Random Sequence   Coin toss, Lottery, toss of dice, shuffling cards etc 
Method of Concealment   Sequentially numbered, sealed, opaque envelopes 
Blinding/Masking   Not Applicable 
Primary Outcome  
Outcome  TimePoints 
rate of successful cannulation of radial artery   first attempt 
 
Secondary Outcome  
Outcome  TimePoints 
Total number of attempts,
• The time taken to cannulate, and
• Any complication related to the procedure
 
0,6,24 hrs 
 
Target Sample Size   Total Sample Size="100"
Sample Size from India="100" 
Final Enrollment numbers achieved (Total)= "Applicable only for Completed/Terminated trials"
Final Enrollment numbers achieved (India)="Applicable only for Completed/Terminated trials" 
Phase of Trial   N/A 
Date of First Enrollment (India)   10/07/2021 
Date of Study Completion (India) Applicable only for Completed/Terminated trials 
Date of First Enrollment (Global)  Date Missing 
Date of Study Completion (Global) Applicable only for Completed/Terminated trials 
Estimated Duration of Trial   Years="0"
Months="3"
Days="0" 
Recruitment Status of Trial (Global)   Not Applicable 
Recruitment Status of Trial (India)  Not Yet Recruiting 
Publication Details   PROSPECTIVE RANDOMISED CONTROL TRIAL. Compare the novel transducer technique which provides more objective evidence in threading the cannula during arterial cannulation and reduces its complications 
Individual Participant Data (IPD) Sharing Statement

Will individual participant data (IPD) be shared publicly (including data dictionaries)?  

Response - NO
Brief Summary   Transducer technique is a novel method for cannulation of the artery for blood pressure monitoring and sampling of blood for arterial blood gas analysis, in this study we want to compare the first pass success rate, time taken to cannulate, and complications in this novel method as compared to the traditional palpatory method of radial artery cannulation  
Close