| CTRI Number |
CTRI/2021/01/030724 [Registered on: 22/01/2021] Trial Registered Prospectively |
| Last Modified On: |
22/01/2021 |
| Post Graduate Thesis |
No |
| Type of Trial |
Interventional |
|
Type of Study
|
Diagnostic Screening Other (Specify) [Smartphone App and Virtual headset to measure IOP,VA& visual field testing] |
| Study Design |
Non-randomized, Multiple Arm Trial |
|
Public Title of Study
|
Glaucoma screening using smartphones |
|
Scientific Title of Study
|
To develop, evaluate the clinical usage and diagnostic performance
clinieally for smartphone based scalable eyecare applications like IOP measurements, visual acuity & VR Headset based visual field testing for glaucoma screening & progression management." |
| Trial Acronym |
|
|
Secondary IDs if Any
|
| Secondary ID |
Identifier |
| NIL |
NIL |
|
|
Details of Principal Investigator or overall Trial Coordinator (multi-center study)
|
| Name |
Dr Arvind Kumar Morya |
| Designation |
Associate Professor |
| Affiliation |
All India Institute of Medical Science |
| Address |
Department of Ophthalmology
All India Institute of Medical Sciences,Basni Industrial area, MIA 2nd Phase,
Jodhpur RAJASTHAN 342005 India |
| Phone |
9812403786 |
| Fax |
|
| Email |
bulbul.morya@gmail.com |
|
Details of Contact Person Scientific Query
|
| Name |
Dr Arvind Kumar Morya |
| Designation |
Associate Professor |
| Affiliation |
All India Institute of Medical Science |
| Address |
Department of Ophthalmology
All India Institute of Medical Sciences,Basni Industrial area, MIA 2nd Phase,
RAJASTHAN 342005 India |
| Phone |
9812403786 |
| Fax |
|
| Email |
bulbul.morya@gmail.com |
|
Details of Contact Person Public Query
|
| Name |
Dr Arvind Kumar Morya |
| Designation |
Associate Professor |
| Affiliation |
All India Institute of Medical Science |
| Address |
Department of Ophthalmology
All India Institute of Medical Sciences,Basni Industrial area, MIA 2nd Phase,
RAJASTHAN 342005 India |
| Phone |
9812403786 |
| Fax |
|
| Email |
bulbul.morya@gmail.com |
|
|
Source of Monetary or Material Support
|
|
|
Primary Sponsor
|
| Name |
Dr Arvind kumar morya |
| Address |
Department of Ophthalmology
All India Institute of Medical Sciences,Basni Industrial area, MIA 2nd Phase, 342005 |
| Type of Sponsor |
Other [self funded by Dr Arvind kumar morya] |
|
|
Details of Secondary Sponsor
|
|
|
Countries of Recruitment
|
India |
|
Sites of Study
|
| No of Sites = 4 |
| Name of Principal
Investigator |
Name of Site |
Site Address |
Phone/Fax/Email |
| Dr Vijay Gupta |
RNT Medical College, Udaipur |
Room No.3,Dept. of Ophthalmology, RNT Medical College,Court Chowk, Citys Prime Health Care Area, Udaipur, Rajasthan 313001 Udaipur RAJASTHAN |
941416658
vijaygupta19682@yahoo.com |
| Dr Arvind Kumar Morya |
All India Institute of Medical Sciences, Jodhpur |
Room no.424, Dept. of Ophthalmology, AIIMS, Basni Industrial Area, MIA 2nd Phase, Basni, Jodhpur, Rajasthan 342005 Jodhpur RAJASTHAN |
9812403786
bulbul.morya@gmail.com |
| Dr Lipa Mohanty |
Geetanjali Medical College and hospital, Udaipur Udaipur |
Room no. 4, Dept. of Ophthalmology, Geetanjali Medical College,Hiranmagri Extension, Manwakhera NH-8 Bypass, Near Eklingpura, Chouraha, Udaipur, Rajasthan 313001 Udaipur RAJASTHAN |
9928812280
drlipamohanty@gmail.com |
| Dr Rajendra Prasad |
RP Eye Institute,New Delhi |
Room no 3, Dept. of Ophthalmology,RP Eye Institute,B-1, 1201, Pocket 1, Sector B, Vasant Kunj, New Delhi, Delhi 110070 New Delhi DELHI |
9810046823
rpeyeinstitute@gmail.com |
|
|
Details of Ethics Committee
|
| No of Ethics Committees= 4 |
| Name of Committee |
Approval Status |
| Institutional ethical committee, Jodhpur |
Submittted/Under Review |
| Institutional Ethics Committee, Geetanjali Medical College Udaipur |
Submittted/Under Review |
| Institutional Ethics Committee,R P Eye Institute , New Delhi |
Submittted/Under Review |
| Institutional Ethics Committee,R.N.T Medical College Udaipur |
Approved |
|
|
Regulatory Clearance Status from DCGI
|
|
|
Health Condition / Problems Studied
|
| Health Type |
Condition |
| Patients |
(1) ICD-10 Condition: H409||Unspecified glaucoma, |
|
|
Intervention / Comparator Agent
|
| Type |
Name |
Details |
| Intervention |
Screening of glaucoma using smart phone based App to measure Intraocular pressure , visual acuity and virtual reality based headset for visual field testing. |
Intraocular pressure(IOP), Perimtery(Visual field testing), visual acuity measurement in suitable patients of glaucoma and non -glaucoma using virtual reality based headset and smartphone app. |
|
|
Inclusion Criteria
|
| Age From |
20.00 Year(s) |
| Age To |
70.00 Year(s) |
| Gender |
Both |
| Details |
1. Patients in the age group of 20 – 70 years.
2. Patients willing to give written informed consent.
|
|
| ExclusionCriteria |
| Details |
1. Patients who are not unable to understand the procedure.
2. Patients having the retinal pathologies.
3. Patients who have vision BCVA less than 6/60.
4. Patients having contagious communicable disease.
|
|
|
Method of Generating Random Sequence
|
|
|
Method of Concealment
|
|
|
Blinding/Masking
|
|
|
Primary Outcome
|
| Outcome |
TimePoints |
| The primary objectives of this study are Virtual Reality based Visual Field Testing and Anterior segment imaging based IntraOcular Pressure (IOP) estimation and Visual Acuity assessment. |
OPD Day 1 and OPD Day 3 |
|
|
Secondary Outcome
|
| Outcome |
TimePoints |
| a secondary objective is to validate the use of a smartphone based Visual Acuity Test without any ophthalmic apparatus thus paving the way to a prospective tele-ophthalmology application. |
18 MONTHS |
|
|
Target Sample Size
|
Total Sample Size="3000" Sample Size from India="3000"
Final Enrollment numbers achieved (Total)= "Applicable only for Completed/Terminated trials"
Final Enrollment numbers achieved (India)="Applicable only for Completed/Terminated trials" |
|
Phase of Trial
|
Phase 4 |
|
Date of First Enrollment (India)
|
01/02/2021 |
| Date of Study Completion (India) |
Applicable only for Completed/Terminated trials |
| Date of First Enrollment (Global) |
Date Missing |
| Date of Study Completion (Global) |
Applicable only for Completed/Terminated trials |
|
Estimated Duration of Trial
|
Years="1" Months="6" Days="0" |
|
Recruitment Status of Trial (Global)
|
Not Applicable |
| Recruitment Status of Trial (India) |
Not Yet Recruiting |
|
Publication Details
|
NIL |
|
Individual Participant Data (IPD) Sharing Statement
|
Will individual participant data (IPD) be shared publicly (including data dictionaries)?
Response - NO
|
|
Brief Summary
|
The primary objectives of this study are to - VR based VFT and
Anterior segment imaging based IntraOcular Pressure (IOP) estimation. The third
one, a secondary objective is to validate the use of a smartphone based Visual
Acuity Test without any ophthalmic apparatus thus paving the way to a
prospective tele-ophthalmology application. VFT tests show good correlation for glaucoma diagnosis but are
conducted using heavy and expensive equipment and it being a time-consuming and
patient focus oriented test.
|