CTRI Number |
CTRI/2020/05/025480 [Registered on: 29/05/2020] Trial Registered Prospectively |
Last Modified On: |
27/05/2020 |
Post Graduate Thesis |
Yes |
Type of Trial |
Interventional |
Type of Study
|
Surgical/Anesthesia |
Study Design |
Single Arm Study |
Public Title of Study
|
Accuracy assessment of deformity correction using computer guided newer generation external fixator in deformities of thigh and leg bones |
Scientific Title of Study
|
Evaluation of accuracy of bony alignment using computer assisted hexapod fixator in correction of long bone deformities of lower limb |
Trial Acronym |
|
Secondary IDs if Any
|
Secondary ID |
Identifier |
NIL |
NIL |
|
Details of Principal Investigator or overall Trial Coordinator (multi-center study)
|
Name |
Anubhav Vichitra |
Designation |
PG resident MS Orthopaedics |
Affiliation |
Maulana Azad Medical College |
Address |
Department of Orthopaedics, Maulana Azad Medical College, Delhi,Bahadur Shah Zafar Marg, Delhi
Central DELHI 110002 India |
Phone |
9654737879 |
Fax |
|
Email |
anu.thundercharge@gmail.com |
|
Details of Contact Person Scientific Query
|
Name |
Dr Vinod Kumar |
Designation |
Director Professor, Department of Orthopaedics, LNH |
Affiliation |
Lok Nayak Hospital |
Address |
Lok Nayak Hospital,Jawaharlal Nehru Marg, Delhi Gate,Delhi
Central DELHI 110002 India |
Phone |
9654737879 |
Fax |
|
Email |
drvk706@gmail.com |
|
Details of Contact Person Public Query
|
Name |
Dr Vinod Kumar |
Designation |
Director Professor, Department of Orthopaedics, LNH |
Affiliation |
Lok Nayak Hospital |
Address |
Lok Nayak Hospital,Jawaharlal Nehru Marg, Delhi Gate,Delhi
DELHI 110002 India |
Phone |
9654737879 |
Fax |
|
Email |
drvk706@gmail.com |
|
Source of Monetary or Material Support
|
Maulana Azad Medical College, Bahadur Shah Safar Marg, New Delhi 110002 |
|
Primary Sponsor
|
Name |
Maulana Azad Medical College |
Address |
Bahadur Shah Safar Marg, New Delhi 110002 |
Type of Sponsor |
Government medical college |
|
Details of Secondary Sponsor
|
|
Countries of Recruitment
|
India |
Sites of Study
|
No of Sites = 1 |
Name of Principal
Investigator |
Name of Site |
Site Address |
Phone/Fax/Email |
Anubhav Vichitra |
Lok Nayak Hospital |
Jawaharlal Nehru Marg, Delhi Gate, New Delhi, 110002 Central DELHI |
9654737879
anu.thundercharge@gmail.com |
|
Details of Ethics Committee
|
No of Ethics Committees= 1 |
Name of Committee |
Approval Status |
Institutional EthicsCommittee, MaulanaAzad Medical College |
Approved |
|
Regulatory Clearance Status from DCGI
|
|
Health Condition / Problems Studied
|
Health Type |
Condition |
Patients |
(1) ICD-10 Condition: M958||Other specified acquired deformities of musculoskeletal system, |
|
Intervention / Comparator Agent
|
Type |
Name |
Details |
Intervention |
Computer assisted hexapod fixator |
Correction of long bone deformities of lower limb using computer assisted hexapod fixator |
Comparator Agent |
NIL |
NIL |
|
Inclusion Criteria
|
Age From |
18.00 Year(s) |
Age To |
60.00 Year(s) |
Gender |
Both |
Details |
1.Clinico-radiologically diagnosed cases of lower limb deformities requiring treatment by Ilizarov method
2.Ilizarov fixator treated lower limb deformity cases with residual deformity after intra-operative acute correction manoeuvre
|
|
ExclusionCriteria |
Details |
1.Ilizarov fixator treated lower limb deformity cases where acceptable bony alignment could be achieved intra-operatively
2.Injuries on ipsilateral limb requiring vascular repair |
|
Method of Generating Random Sequence
|
Not Applicable |
Method of Concealment
|
Not Applicable |
Blinding/Masking
|
Not Applicable |
Primary Outcome
|
Outcome |
TimePoints |
Accuracy of deformity correction will be assessed by following :
A. Residual Angulation at CORA
B. Reference line and angles
C. Value of residual torsional component of deformity, determined clinically
D. Residual Limb length discrepancy (LLD)
Opposite side alignment values will be considered as normal reference values. In case opposite side is also involved, standard reference values will be considered as normal values for evaluation purpose.
|
Primary outcomes will be assessed at two timepoints –
1. Immediately after application of computer assisted hexapod external fixator in postoperative period
2. After completion of software prescribed correction manoeuvre |
|
Secondary Outcome
|
Outcome |
TimePoints |
A. Manner’s grading of deformity (for accuracy assessment)2
B. Time period of Deformity correction
C. Difficulty, Problems and Complications, if any
|
Secondary outcomes will be measured at following timepoint
1. After removal of computer guided external fixator frame
|
|
Target Sample Size
|
Total Sample Size="10" Sample Size from India="10"
Final Enrollment numbers achieved (Total)= "Applicable only for Completed/Terminated trials"
Final Enrollment numbers achieved (India)="Applicable only for Completed/Terminated trials" |
Phase of Trial
|
N/A |
Date of First Enrollment (India)
|
01/06/2020 |
Date of Study Completion (India) |
Applicable only for Completed/Terminated trials |
Date of First Enrollment (Global) |
Date Missing |
Date of Study Completion (Global) |
Applicable only for Completed/Terminated trials |
Estimated Duration of Trial
|
Years="1" Months="0" Days="0" |
Recruitment Status of Trial (Global)
|
Not Applicable |
Recruitment Status of Trial (India) |
Not Yet Recruiting |
Publication Details
|
NIL |
Individual Participant Data (IPD) Sharing Statement
|
Will individual participant data (IPD) be shared publicly (including data dictionaries)?
|
Brief Summary
|
This study has been designed as a prospective interventional study to evaluate the accuracy of bony alignment using computer assisted hexapod fixator in correction of long bone deformities of lower limb in patients of age group of 18-60 years. Study will be conducted in India for a duration of 1 year. Outcome of the study will be assessed by residual angulation at CORA, reference lines and angles, residual LLD, time period of deformity correction, number of correction manoeuvres required. |