FULL DETAILS (Read-only)  -> Click Here to Create PDF for Current Dataset of Trial
CTRI Number  CTRI/2020/10/028480 [Registered on: 20/10/2020] Trial Registered Prospectively
Last Modified On: 19/10/2020
Post Graduate Thesis  Yes 
Type of Trial  Observational 
Type of Study   outcome assesor blinded 
Study Design  Single Arm Study 
Public Title of Study   Correlation of lung ultrasound score with oxygenation in pneumonia 
Scientific Title of Study   Correlation of Lung Ultrasound aeration score with Oxygenation in Ventilator associated pneumonia (VAP) 
Trial Acronym   
Secondary IDs if Any  
Secondary ID  Identifier 
NIL  NIL 
 
Details of Principal Investigator or overall Trial Coordinator (multi-center study)  
Name  SAGARIKA PANDA 
Designation  SR Academic 
Affiliation  AIIMS RISHIKESH 
Address  DEPARTMENT OF ANAESTHESIOLOGY AIIMS RISHIKESH VIRBHADRA MARG RISHIKESH

Dehradun
UTTARANCHAL
249203
India 
Phone  08280097212  
Fax    
Email  sp.ruby@gmail.com  
 
Details of Contact Person
Scientific Query
 
Name  Dr ANKIT AGARWAL 
Designation  Additional Professor 
Affiliation  AIIMS RISHIKESH 
Address  DEPARTMENT OF ANAESTHESIOLOGY AIIMS RISHIKESH VIRBHADRA MARG RISHIKESH

Dehradun
UTTARANCHAL
249203
India 
Phone  08475000280  
Fax    
Email  drankit80@gmail.com  
 
Details of Contact Person
Public Query
 
Name  Dr ANKIT AGARWAL 
Designation  Additional Prfessor 
Affiliation  AIIMS RISHIKESH 
Address  DEPARTMENT OF ANAESTHESIOLOGY AIIMS RISHIKESH VIRBHADRA MARG RISHIKESH

Dehradun
UTTARANCHAL
249203
India 
Phone  08475000280  
Fax    
Email  drankit80@gmail.com  
 
Source of Monetary or Material Support  
DEPARTMENT OF ANAESTHESIOLOGY, AIIMS RISHIKESH, UTTARAKHAND 
 
Primary Sponsor  
Name  None 
Address  NA 
Type of Sponsor  Other [NA] 
 
Details of Secondary Sponsor  
Name  Address 
None  NA 
 
Countries of Recruitment     India  
Sites of Study  
No of Sites = 1  
Name of Principal Investigator  Name of Site  Site Address  Phone/Fax/Email 
Sagarika Panda  AIIMS RISHIKESH  CRITICAL CARE UNIT, LEVEL 06 DEPARTMENT OF ANAESTHESIOLOGY
Dehradun
UTTARANCHAL 
08280097212

sp.ruby@gmail.com 
 
Details of Ethics Committee  
No of Ethics Committees= 1  
Name of Committee  Approval Status 
Institutional Ethics Commitee  Approved 
 
Regulatory Clearance Status from DCGI  
Status 
Not Applicable 
 
Health Condition / Problems Studied  
Health Type  Condition 
Patients  (1) ICD-10 Condition: J189||Pneumonia, unspecified organism, (2) ICD-10 Condition: J189||Pneumonia, unspecified organism,  
 
Intervention / Comparator Agent  
Type  Name  Details 
Intervention  NIL  NIL 
Intervention  NIL  NIL 
Intervention  NIL  NIL 
 
Inclusion Criteria  
Age From  18.00 Year(s)
Age To  60.00 Year(s)
Gender  Both 
Details  Patient fulfilling the diagnosis criteria of VAP(as per Clinical Pulmonary Infection Score ) 
 
ExclusionCriteria 
Details  1. Evidence of disseminated malignancy.
2. Pregnancy.
3. Thoracic dressings.
4. Subcutaneous emphysema.
5. Chronic obstructive pulmonary disease.
6. Interstitial lung disease.
7. Morbid obesity
 
 
Method of Generating Random Sequence   Not Applicable 
Method of Concealment   Not Applicable 
Blinding/Masking   Outcome Assessor Blinded 
Primary Outcome  
Outcome  TimePoints 
1.Correlation between Lung ultrasound aeration score and lung compliance
2.Correlation betwwen lung ultrasound aeration score and arterial oxygenation .
 
Started on suscipicion of Ventilator associated pneumonia as day 1 to be done for 5 days at 9 am in the morning 
 
Secondary Outcome  
Outcome  TimePoints 
1. Correlation between day 1 Lung ultrasound score and 28-day mortality
2. Correlation between day 1 Lung ultrasound score and duration of mechanical ventilation
 
Day 1 on inclusion into the study to Day 28  
 
Target Sample Size   Total Sample Size="55"
Sample Size from India="55" 
Final Enrollment numbers achieved (Total)= "Applicable only for Completed/Terminated trials"
Final Enrollment numbers achieved (India)="Applicable only for Completed/Terminated trials" 
Phase of Trial   N/A 
Date of First Enrollment (India)   11/11/2020 
Date of Study Completion (India) Applicable only for Completed/Terminated trials 
Date of First Enrollment (Global)  Date Missing 
Date of Study Completion (Global) Applicable only for Completed/Terminated trials 
Estimated Duration of Trial   Years="1"
Months="0"
Days="0" 
Recruitment Status of Trial (Global)   Not Applicable 
Recruitment Status of Trial (India)  Not Yet Recruiting 
Publication Details   NIL 
Individual Participant Data (IPD) Sharing Statement

Will individual participant data (IPD) be shared publicly (including data dictionaries)?  

Brief Summary   Ventilator associated pneumonia is one of the major cause of hospital acquired infection, which leads to increase ICU and hospital length of stay . There is no single gold standard test for its diagnosis and monitoring.Chest xray has less specificity in supine critically ill patient and CT scan expose the sick patients to transport out of ICU .Ultrasound is a simple , non invasive and raditaion free device  for diagnosing consolidation in Ventilator associated peumonia patients , On suspicion of development of ventilator associted pneumonia ,lung ultrasound will be done to calculate lung aeration score , and at the same time artrial blood gas will be obtain to measure PaO2/FiO2 ratio and from inspiratory pause maneuver on ventilator  static lung  compliance will be measured .Patients will bve followed up for 28 days from the day of first inclusion into the study . 
Close