FULL DETAILS (Read-only)  -> Click Here to Create PDF for Current Dataset of Trial
CTRI Number  CTRI/2026/04/107234 [Registered on: 01/04/2026] Trial Registered Prospectively
Last Modified On: 30/03/2026
Post Graduate Thesis  Yes 
Type of Trial  Interventional 
Type of Study   Dentistry 
Study Design  Other 
Public Title of Study   Comparing the accuracy of CAD-CAM (computer aided design computer aided manufacturing) printed surgical guide vs a conventional thermoplastic surgical guide using cone beam computed tomography- An in vivo study 
Scientific Title of Study   Comparing the accuracy of CAD-CAM (computer aided design computer aided manufacturing) printed surgical guide vs a conventional thermoplastic surgical guide using cone beam computed tomography (CBCT)- An in vivo study 
Trial Acronym  nil 
Secondary IDs if Any  
Secondary ID  Identifier 
NIL  NIL 
 
Details of Principal Investigator or overall Trial Coordinator (multi-center study)  
Name  Dr Hritika Gawande 
Designation  MDS student 
Affiliation  Government college of dentistry indore 
Address  room no 7 Dept of Prosthodontics Govt College of dentistry Indore 452001

Indore
MADHYA PRADESH
452001
India 
Phone  09754941964  
Fax    
Email  gawandehritika@gmail.com  
 
Details of Contact Person
Scientific Query
 
Name  Dr. Harsh Chansoria 
Designation  Associate Professor 
Affiliation  Government college of dentistry indore 
Address  room no 7 Dept of Prosthodontics Govt College of Dentistry Indore 452001

Indore
MADHYA PRADESH
452001
India 
Phone  9425016952  
Fax    
Email  harsh.chansoria@gmail.com  
 
Details of Contact Person
Public Query
 
Name  Dr Hritika Gawande 
Designation  MDS student 
Affiliation  Government college of dentistry indore 
Address  Room no 7 Dept of Prosthodontics Govt College of Dentistry Indore

Indore
MADHYA PRADESH
452001
India 
Phone  9754941964  
Fax    
Email  gawandehritika@gmail.com  
 
Source of Monetary or Material Support  
Govt. College of Dentistry, indore 
 
Primary Sponsor  
Name  Dr hritika gawande 
Address  Govt college of dentistry indore Madhya Pradesh 452001 
Type of Sponsor  Other [Self] 
 
Details of Secondary Sponsor  
Name  Address 
NIL  NIL 
 
Countries of Recruitment     India  
Sites of Study  
No of Sites = 1  
Name of Principal Investigator  Name of Site  Site Address  Phone/Fax/Email 
Dr Hritika Gawande  Govt. College of Dentistry, indore  Govt college of dentistry, indore Madhya Pradesh 452001
Indore
MADHYA PRADESH 
09754941964

gawandehritika@gmail.com 
 
Details of Ethics Committee  
No of Ethics Committees= 1  
Name of Committee  Approval Status 
Institutional ethics committee  Approved 
 
Regulatory Clearance Status from DCGI  
Status 
Not Applicable 
 
Health Condition / Problems Studied  
Health Type  Condition 
Patients  (1) ICD-10 Condition: K039||Disease of hard tissues of teeth,unspecified,  
 
Intervention / Comparator Agent  
Type  Name  Details 
Intervention  CAD CAM guide  accuracy of cad cam milled thermoplastic guide will be compared to a conventional thermoplastic guide 
Comparator Agent  thermoplastic guide  Cad Cam milled implant guide will be compared to a conventionalthermoplastic surgical guide 
 
Inclusion Criteria  
Age From  18.00 Year(s)
Age To  90.00 Year(s)
Gender  Both 
Details  1. Adult patients (18 years and above).
2. Systemically and periodontally healthy.
3. Edentulous sites with intact adjacent teeth in maxillary anterior and premolar region.
4. Patients consenting for cone beam computed tomography (CBCT) scanning as part of treatment planning
 
 
ExclusionCriteria 
Details  • The presence of active periodontal disease and medical conditions that are contraindicated for implant therapy 
 
Method of Generating Random Sequence   Coin toss, Lottery, toss of dice, shuffling cards etc 
Method of Concealment   Not Applicable 
Blinding/Masking   Outcome Assessor Blinded 
Primary Outcome  
Outcome  TimePoints 
the key referecnce article used for sample collection stated that positional accuracy of CAD CAM printed guide was more than conventional thermoplastic guide.  the time period is 7 days, comparing the outcome to the planned position of implant. 
 
Secondary Outcome  
Outcome  TimePoints 
nil  nil 
 
Target Sample Size   Total Sample Size="20"
Sample Size from India="20" 
Final Enrollment numbers achieved (Total)= "Applicable only for Completed/Terminated trials"
Final Enrollment numbers achieved (India)="Applicable only for Completed/Terminated trials" 
Phase of Trial   Phase 1/ Phase 2 
Date of First Enrollment (India)   15/04/2026 
Date of Study Completion (India) Applicable only for Completed/Terminated trials 
Date of First Enrollment (Global)  Date Missing 
Date of Study Completion (Global) Applicable only for Completed/Terminated trials 
Estimated Duration of Trial   Years="2"
Months="0"
Days="0" 
Recruitment Status of Trial (Global)   Not Yet Recruiting 
Recruitment Status of Trial (India)  Not Yet Recruiting 
Publication Details   N/A 
Individual Participant Data (IPD) Sharing Statement

Will individual participant data (IPD) be shared publicly (including data dictionaries)?  

Response - YES
  1. What data in particular will be shared?
    Response - Individual participant data that underlie the results reported in this article, after de-identification (text, tables, figures, and appendices).

  2. What additional supporting information will be shared?
    Response -  Study Protocol
    Response -  Statistical Analysis Plan
    Response - Informed Consent Form
    Response - Clinical Study Report

  3. Who will be able to view these files?
    Response - Researchers whose proposed use of the data has been approved by an independent review committee identified for this purpose.

  4. For what types of analyses will this data be available?
    Response - To achieve aims in the approved proposal.

  5. By what mechanism will data be made available?
    Response - Proposals should be directed to [gawandehritika@gmail.com].

  6. For how long will this data be available start date provided 31-12-2027 and end date provided 01-01-2030?
    Response - Immediately following publication. No end date.

  7. Any URL or additional information regarding plan/policy for sharing IPD? 
    Additional Information - nil
Brief Summary  

The aim of this study is to compare the accuracy of implant placement using CAD CAM printed surgical guide and a conventional thermoplastic surgical guide using cone beam computed tomography.

 

 

The objective is:

·      To determine the dimensional deviations in the planned and placed implant position using a conventional thermoplastic surgical guide.

·      To determine the dimensional deviations in the planned and placed implant position using a 3D CAD-CAM printed guide template.

To compare the accuracy of implant placement by a conventional thermoplastic surgical guide to a CAD-CAM printed surgical guide using cone beam computed tomography 
Close