FULL DETAILS (Read-only)  -> Click Here to Create PDF for Current Dataset of Trial
CTRI Number  CTRI/2024/11/076346 [Registered on: 06/11/2024] Trial Registered Prospectively
Last Modified On: 06/11/2024
Post Graduate Thesis  Yes 
Type of Trial  Interventional 
Type of Study   Medical Device 
Study Design  Randomized, Parallel Group Trial 
Public Title of Study   A clinical trial to compare efficiency of D-Stylet and rigid stylet using videolaryngoscope in difficult intubation cases 
Scientific Title of Study   Comparison of D-Stylet and rigid stylet using videolaryngoscope in difficult intubation 
Trial Acronym  NIL 
Secondary IDs if Any  
Secondary ID  Identifier 
NIL  NIL 
 
Details of Principal Investigator or overall Trial Coordinator (multi-center study)  
Name  Dr Shikha Gupta 
Designation  Professor Anaesthesia 
Affiliation  Dayanand Medical College and Hospital 
Address  Department of Anaesthesia Dayanand Medical College and Hospital Civil Lines Ludhiana 141001 Punjab India Ludhiana PUNJAB 141001 India Ludhiana PUNJAB 141001 India

Ludhiana
PUNJAB
141001
India 
Phone  9814820622  
Fax    
Email  shikhadmc@yahoo.com  
 
Details of Contact Person
Scientific Query
 
Name  Dr Ajay Kumar 
Designation  PG Resident Anaesthesia 
Affiliation  Dayanand Medical College and Hospital 
Address  Department of Anaesthesia Dayanand Medical College and Hospital Civil Lines Ludhiana 141001 Punjab India Ludhiana PUNJAB 141001 India Ludhiana PUNJAB 141001 India

Ludhiana
PUNJAB
141001
India 
Phone  7973356187  
Fax    
Email  akay7589@gmail.com  
 
Details of Contact Person
Public Query
 
Name  Dr Ajay Kumar 
Designation  PG Resident Anaesthesia 
Affiliation  Dayanand Medical College and Hospital 
Address  Department of Anaesthesia Dayanand Medical College and Hospital Civil Lines Ludhiana 141001 Punjab India Ludhiana PUNJAB 141001 India Ludhiana PUNJAB 141001 India

Ludhiana
PUNJAB
141001
India 
Phone  7973356187  
Fax    
Email  akay7589@gmail.com  
 
Source of Monetary or Material Support  
Dayanand Medical College and Hospital Ludhiana 141001 Punjab INDIA  
 
Primary Sponsor  
Name  Dayanand Medical college and Hospital 
Address  Tagore Nagar, Civil lines, Ludhiana. 141001 Punjab India 
Type of Sponsor  Private medical college 
 
Details of Secondary Sponsor  
Name  Address 
NIL  NIL 
 
Countries of Recruitment     India  
Sites of Study  
No of Sites = 1  
Name of Principal Investigator  Name of Site  Site Address  Phone/Fax/Email 
Dr Shikha Gupta  Dayanad Medical College and Hospital  Department of Anaesthesia Dayanand Medical College and Hospital Tagore Nagar, Civil Lines Ludhiana 141001 Ludhiana PUNJAB Ludhiana PUNJAB
Ludhiana
PUNJAB 
9814820622

shikhadmc@yahoo.com 
 
Details of Ethics Committee  
No of Ethics Committees= 1  
Name of Committee  Approval Status 
Research and Ethical Committee Dayanand Medical College and Hospital  Approved 
 
Regulatory Clearance Status from DCGI  
Status 
Not Applicable 
 
Health Condition / Problems Studied  
Health Type  Condition 
Patients  (1) ICD-10 Condition: 8||Other Procedures,  
 
Intervention / Comparator Agent  
Type  Name  Details 
Intervention  D Stylet intubation  In anticipated difficult intubation patients, video-laryngoscopic intubation will be done using D Stylet 
Comparator Agent  Rigid stylet intubation  In anticipated difficult intubation patients, video-laryngoscopic intubation will be done using portex Rigid stylet 
 
Inclusion Criteria  
Age From  18.00 Year(s)
Age To  99.00 Year(s)
Gender  Both 
Details  1.Age more than or equal to 18 yrs
2.Either sex
3.American Society of Anaesthesiologists grade 1-4
4.Patients with Anticipated difficult airway more than 6
 
 
ExclusionCriteria 
Details  1.Known airway pathology
2.Head and neck known malignancy
3.Immobilized cervical spine
4.Pregnancy
5.Increased risk of regurgitation and aspiration of gastric contents
6.Patient refusal
 
 
Method of Generating Random Sequence   Computer generated randomization 
Method of Concealment   Sequentially numbered, sealed, opaque envelopes 
Blinding/Masking   Participant Blinded 
Primary Outcome  
Outcome  TimePoints 
Comparison of successful Endotracheal tube time between videolaryngoscopic inubation using D Sylet and Portex Rigid Stylet  Time used between receiving the styleted endotracheal tube in the laryngoscopists hand and the successful passage of black line on endotracheal tube just beyond the vocal cord, measured in seconds. 
 
Secondary Outcome  
Outcome  TimePoints 
Difference in total intubation time, number of attempts for successful intubation, hemodynamic changes, and any airway trauma between both the groups  Total intubation time- From start to end of intubation procedure.
Number of attempts-Number of attempts recorded as part of procedure.
Hemodynamic changes-after induction, immediately post-intubation (0 min) and at 1, 5, and 10-minutes post-intubation.
Airway trauma- immediately post intubation 
 
Target Sample Size   Total Sample Size="232"
Sample Size from India="232" 
Final Enrollment numbers achieved (Total)= "Applicable only for Completed/Terminated trials"
Final Enrollment numbers achieved (India)="Applicable only for Completed/Terminated trials" 
Phase of Trial   Phase 4 
Date of First Enrollment (India)   21/11/2024 
Date of Study Completion (India) Applicable only for Completed/Terminated trials 
Date of First Enrollment (Global)  Date Missing 
Date of Study Completion (Global) Applicable only for Completed/Terminated trials 
Estimated Duration of Trial   Years="1"
Months="6"
Days="0" 
Recruitment Status of Trial (Global)   Not Applicable 
Recruitment Status of Trial (India)  Not Yet Recruiting 
Publication Details   N/A 
Individual Participant Data (IPD) Sharing Statement

Will individual participant data (IPD) be shared publicly (including data dictionaries)?  

Response - NO
Brief Summary   The use of stylet with an endotracheal tube (ETT) in anticipated difficult airway patients using videolaryngoscope(VL) has decreased the incidence of failed intubations. Commonly used Portex® rigid stylet forms a fixed shape and curvature of ETT, which at times does not match with the angle and curvature of the D-blade C-MAC videolaryngoscope. This necessitates the withdrawal of ETT-stylet assembly for reshaping. On the other hand, the D-stylet has an easily controllable flexible tip, which can be used as a dynamic aid to tailor the ETT shape and its tip can be altered as required by the intubating personnel according to the angle of the D-Blade. A prospective, interventional, single-blinded study will be conducted on a total of 232 patients having anticipated difficult airway undergoing elective tracheal intubation with a D-blade videolaryngoscope. The patients will be divided into the following two groups- In group D intubation will be done on 116 patients using D-Stylet while Portex® rigid stylet will be used in Group P on the other 116 patients. Aim of our study is the Comparison of D-stylet with rigid stylet as a dynamic aid to facilitate intubation in anticipated difficult airway using a D-blade videolaryngoscope. The primary outcome of our study is difference in ETT negotiation time between both groups and the secondary outcome is difference in total intubation time, number of attempts for successful intubation, hemodynamic changes, and any airway trauma between both the groups.

 

 