FULL DETAILS (Read-only)  -> Click Here to Create PDF for Current Dataset of Trial
CTRI Number  CTRI/2024/09/073601 [Registered on: 09/09/2024] Trial Registered Prospectively
Last Modified On: 07/09/2024
Post Graduate Thesis  No 
Type of Trial  Interventional 
Type of Study   Physiotherapy (Not Including YOGA) 
Study Design  Other 
Public Title of Study   Designing and Creating a New Medical Device: A Simple Solution for Shoulder Problems 
Scientific Title of Study   Designing and Developing a Novel Medical Device Prototype, One Stop Solution for Shoulder Dysfunction – An Exploratory Multiphasic Study 
Trial Acronym  NIL 
Secondary IDs if Any  
Secondary ID  Identifier 
NIL  NIL 
 
Details of Principal Investigator or overall Trial Coordinator (multi-center study)  
Name  Dr Namrata Sojitra 
Designation  Assistant Professor 
Affiliation  School of Physiotherapy, RK University 
Address  Research Department, Room no. 207, School of Physiortherapy, RK University kasturbadham Rajkot-Bhavnagar Highway, Rajkot, Gujarat, India. Rajkot GUJARAT 360020 India

Rajkot
GUJARAT
360020
India 
Phone  9427110124  
Fax    
Email  namrata.sojitra@rku.ac.in  
 
Details of Contact Person
Scientific Query
 
Name  Dr Namrata Sojitra 
Designation  Assistant Professor 
Affiliation  School of Physiotherapy, RK University 
Address  Research Department, Room no. 207, School of Physiortherapy, RK University kasturbadham Rajkot-Bhavnagar Highway, Rajkot, Gujarat, India. Rajkot GUJARAT 360020 India

Rajkot
GUJARAT
360020
India 
Phone  9427110124  
Fax    
Email  namrata.sojitra@rku.ac.in  
 
Details of Contact Person
Public Query
 
Name  Dr Namrata Sojitra 
Designation  Assistant Professor 
Affiliation  School of Physiotherapy, RK University 
Address  Research Department, Room no. 207, School of Physiortherapy, RK University kasturbadham Rajkot-Bhavnagar Highway, Rajkot, Gujarat, India. Rajkot GUJARAT 360020 India

Rajkot
GUJARAT
360020
India 
Phone  9427110124  
Fax    
Email  namrata.sojitra@rku.ac.in  
 
Source of Monetary or Material Support  
School of Physiotherapy, RK University 
 
Primary Sponsor  
Name  Dr. Namrata Sojitra 
Address  Research Department, Room no. 207, School of Physiortherapy, RK University kasturbadham Rajkot-Bhavnagar Highway, Rajkot, Gujarat, India. Rajkot GUJARAT 360020 India 
Type of Sponsor  Other [Self] 
 
Details of Secondary Sponsor  
Name  Address 
NIL  NIL 
 
Countries of Recruitment     India  
Sites of Study  
No of Sites = 1  
Name of Principal Investigator  Name of Site  Site Address  Phone/Fax/Email 
Dr Namrata Sojitra  School of Physiotherapy, RK University  Research Department, Room no. 207, School of Physiortherapy, RK University kasturbadham Rajkot-Bhavnagar Highway, Rajkot, Gujarat, India.
Rajkot
GUJARAT 
9427110124

namrata.sojitra@rku.ac.in 
 
Details of Ethics Committee  
No of Ethics Committees= 1  
Name of Committee  Approval Status 
Institutional Ethical Committee, School of Physiotherapy, RK University, Rajkot  Approved 
 
Regulatory Clearance Status from DCGI  
Status 
Not Applicable 
 
Health Condition / Problems Studied  
Health Type  Condition 
Patients  (1) ICD-10 Condition: M959||Acquired deformity of musculoskeletal system, unspecified,  
 
Intervention / Comparator Agent  
Type  Name  Details 
Intervention  Continuous passive movements, Resisted Exercises, Active assisted exercises  This newly developed device offers one stop solution for shoulder rehabilitation, designed to deliver active-assisted exercises, continuous passive movements, and resisted exercises. To evaluate the devices effectiveness, 40 patients with various shoulder conditions will be selected. Each patient will undergo treatment using the device, which includes continuous passive movements, as well as active-assisted and resisted exercises. The active-assisted and resisted exercises will consist of 10 repetitions targeting shoulder flexion/extension, abduction/adduction, and internal/external rotation. Continuous passive movement therapy will be administered for 15 minutes per session. Training will be conducted 5 days a week for a total of 3 weeks. 
Comparator Agent  N/A  There is no comparator agent because this trial aims to check effectiveness of the device by taking pre and post treatment data. It dose not aim to compare this device with any other treatment regimes 
 
Inclusion Criteria  
Age From  40.00 Year(s)
Age To  60.00 Year(s)
Gender  Both 
Details  Patients with shoulder dysfunction
Patients with restricted shoulder flexion and abduction above 90°
 
 
ExclusionCriteria 
Details  Hyper mobile shoulder joint
Reflex sympathetic Dystrophy
 
 
Method of Generating Random Sequence    
Method of Concealment    
Blinding/Masking    
Primary Outcome  
Outcome  TimePoints 
Goniometry for Range of Motion, Manual muscle testing for muscle strength and NPRS for pain will be primary outcome measures  All the Outcome measures will be measured prior to the intervention and post measurement data will be taken at the end of 3 weeks 
 
Secondary Outcome  
Outcome  TimePoints 
N/A  N/A 
 
Target Sample Size   Total Sample Size="40"
Sample Size from India="40" 
Final Enrollment numbers achieved (Total)= "Applicable only for Completed/Terminated trials"
Final Enrollment numbers achieved (India)="Applicable only for Completed/Terminated trials" 
Phase of Trial   Phase 2/ Phase 3 
Date of First Enrollment (India)   20/09/2024 
Date of Study Completion (India) Applicable only for Completed/Terminated trials 
Date of First Enrollment (Global)  Date Missing 
Date of Study Completion (Global) Applicable only for Completed/Terminated trials 
Estimated Duration of Trial   Years="0"
Months="6"
Days="0" 
Recruitment Status of Trial (Global)   Not Yet Recruiting 
Recruitment Status of Trial (India)  Not Yet Recruiting 
Publication Details   N/A 
Individual Participant Data (IPD) Sharing Statement

Will individual participant data (IPD) be shared publicly (including data dictionaries)?  

Response - NO
Brief Summary  

Background: The shoulder is an unique anatomical structure with an extraordinary Range of Motion (ROM) that allows us to interact with our environment.1 The shoulder consists of three bones and four joints. The shoulder girdle consists of the clavicle, scapular, and humeral head. Among the joints of the shoulder, which are the glenohumeral, sternoclavicular, acromioclavicular, and scapulothoracic joints, the glenohumeral joint is the major shoulder joint that involves a complex articulation between the humeral head and the glenoid cavity of the shoulder girdle. The global elevation range of motion (RoM) of the arm is mainly the result of a coordinated motion between the movements of the GH and ST joints, which contribute 30% to 40% of the total movement of the arm

Shoulder pain is the third most common musculoskeletal disorder, with incidence rates up to 2.5% and prevalence figures that range from 6.9% to 26% for point prevalence, which rise up to 66.7% for lifetime prevalence in the general population.

Continuous Passive Motion (CPM) Machine is a device that used for help patients to move the joints. Passive and continuous movements which generated by CPM Machine can help out patient during doing the rehabilitation to restore joint movement

Aim: To Design and develop a novel medical device prototype for shoulder dysfunction

Materials and Methods: it will be multiphase study with interdisciplinary approach to design and develop a novel device for shoulder dysfunction. Study will be carried out in 3 phases.

Phase-1 Design and develop a therapeutic device for shoulder rehabilitation

Pahse-2 To make sure the device is feasible for patients and physiotherapists

Phase-3 Introducing the device to Patients with shoulder dysfunction

 
Close